Home > Products > Gas Filter

  • Gas Filter

    Gas Filter

    A device that retains dust particles conveyed by the gas and protects the elements in danger (burners, counters, boilers, pressure regulators, etc.) from rapid clogging.

    It consists of a filter cartridge made of washable synthetic material and can be entirely removed for full inspection, cleaning and/or replacement.

    This device is designed with special type O sealing ring, which is convenient to use, it can be used on town gas, natural gas, liquid petroleum gas and other non-aggressive gases.

    --TECHNICAL DATA

     

    Application                               : Non-aggressive gases of the three families (dry gases)

      Working temperature                 : -20 - +70°C

      Maximum operating pressure     :    6 bar

    RP threaded connection             : RP1/2’’ to 2’’ Flanged connections         : DN 5 0 t o DN 1 5 0

      Filter element*                      : Filtering Accuracy 50 µm


    GAS FILTER

    MODEL&DIMENTION

     

     

     

    Model.

    Connection

    A(mm)

    B(mm)

    C(mm)

    WFM15P

    RP 1/2’’ Threaded

    130

    70

    95

    WFM20P

    RP 3/4’’  Threaded

    130

    70

    95

    WFM25P

    RP 1’’      Threaded

    130

    70

    95

    WFM32P

    RP 1 1/4’’ Threaded

    165

    85

    140

    WFM40P

    RP 1 1/2’’ Threaded

    165

    85

    140

    WFM50P

    RP 2’’      Threaded

    160

    110

    140

    WFM50/F

    DN50    Flanged

    215

    155

    165

    WFM65/F

    DN65    Flanged

    290

    180

    210

    WFM80/F

    DN80    Flanged

    310

    190

    210

    WFM100/F

    DN100    Flanged

    350

    200

    255

    WFM125/F

    DN125    Flanged

    410

    275

    295

    WFM150/F

    DN150    Flanged

    480

    300

    330

    FLOW/PRESSURE LOSS CURVE

    gas filier2.jpg

    gas filier3.jpg

    gas filier4.jpg

    gas filier5.jpg

    NSTALLATION REMARKS:

     

    1.All installation/maintenance must be carried out by professionally qualified person. 2.Please close the gas supply valve before installation.

    3.Gas filters are usually installed upstream of proprietary regulating and switching devices. After installation, the arrow direction on filter (3) must point to the using equipment and the filter should be installed anywhere that will not interfere with the normal operation of the equipment.

    4.Care should be taken during installation to avoid debris or metal waste entering the filter.

    5.  For threaded connection, check and make sure the pipe thread is not too long; If the thread is too long, it will damage the filter when screws are installed. The connection of pipes and fittings must match the connection thread of the filter.

    6.For flanged conncetion, check that the inlet and outlet butt flanges match each other. Avoid unnecessary mechanical pressure on the filter. At the same time, calculate the space needed to install the sealing ring. If the gap left after installing the sealing ring is too large, do not close the gap by tightening the filter.

    7.Check the gas after installation to ensure no leakage.

    MAINTENANCE

     

    Change the filter element if the difference between the up and downstream pressure exceeds 10 mbar. We recommend replacing it at least once a year anyways. To replace it, please follow the following procedure:

    -  Shut the gas inlet off by shutting the upstream valve off,

    -  Loosen the screws and remove the cover,

    -  Remove the filter element and clean it carefully or replace it with a new one

    -  Re-install the cover so that the guides inside

    the cover correspond with the filter element, and retighten the screws,

    -  Check that there is no cover leak.


    Share
    INQUIRE NOW
Gas Filter
Description and Application

It consists of a filter cartridge made of washable synthetic material and can be entirely removed for full inspection, cleaning and/or replacement.

This device is designed with special type O sealing ring, which is convenient to use, it can be used on town gas, natural gas, liquid petroleum gas and other non-aggressive gases.


Technical Specification

--TECHNICAL DATA

 

Application                               : Non-aggressive gases of the three families (dry gases)

  Working temperature                 : -20 - +70°C

  Maximum operating pressure     :    6 bar

RP threaded connection             : RP1/2’’ to 2’’ Flanged connections         : DN 5 0 t o DN 1 5 0

  Filter element*                      : Filtering Accuracy 50 µm

Overall Dimensions and item No.

Model.

Connection

A(mm)

B(mm)

C(mm)

WFM15P

RP 1/2’’ Threaded

130

70

95

WFM20P

RP 3/4’’  Threaded

130

70

95

WFM25P

RP 1’’      Threaded

130

70

95

WFM32P

RP 1 1/4’’ Threaded

165

85

140

WFM40P

RP 1 1/2’’ Threaded

165

85

140

WFM50P

RP 2’’      Threaded

160

110

140

WFM50/F

DN50    Flanged

215

155

165

WFM65/F

DN65    Flanged

290

180

210

WFM80/F

DN80    Flanged

310

190

210

WFM100/F

DN100    Flanged

350

200

255

WFM125/F

DN125    Flanged

410

275

295

WFM150/F

DN150    Flanged

480

300

330